Price | Negotiatable |
MOQ | 1 set |
Delivery Time | 30 days |
Brand | HongCe |
Place of Origin | China |
Certification | calibration certificate (cost additional) |
Model Number | SH-9A |
Packaging Details | plywood |
Payment Terms | T/T |
Supply Ability | 10 set /month |
Usage | Impact Testing Machine | Nylon base size | 1000mm*1000mm |
Place of Origin | China | Warranty | 1 Year |
Nylon base hardness | HRR85-100 | Packaging Details | plywood |
Standard | IEC60068-2-75 | Model Number | SH-9A |
Supply Ability | 10 set /month | Certification | calibration certificate (cost additional) |
Brand Name | HongCe | Payment Terms | T/T |
Drop Height | 0-1000mm | Price | Negotiatable |
Delivery Time | 30 days | Minimum Order Quantity | 1 set |
Nylon base thickness | 8mm | Power | 220V 50HZ |
IEC60068-2-75 Impact Testing Machine / Vertical Hammer Test Apparatus 0-1m Drop Height
The
hammer
consists
basically
of
a
striking
element
which
falls
freely
from
rest
through
a
vertical
height,
selected
from
Table
2,
on
to
the
specimen
surface
held
in
a
horizontal
plane.
Impact
Testing
Machine
The
characteristics
of
the
striking
element
shall
comply
with
Table
1
.
The
fall
of
the
striking
element
shall
be
along
a
guideway,
for
example
three
or
four
rails,
with
negligible
braking.
This
guideway
shall
not
rest
on
the
specimen
and
the
striking
element
shall
be
free
of
the
guideway
on
striking
the
specimen.
In
order
to
reduce
the
friction,
the
length
l
of
the
striking
element
shall
not
be
smaller
than
its
diameter
D,
and
a
small
gap
(for
example
1
mm)
shall
be
provided
between
the
striking
element
and
the
guideway.
Impact
Testing
Machine
Standard: IEC 60068-2-75 Test Ehc: vertical hammer, UL498 clause SD7.2
Application: This device is intended to test the mechanical strength test of the shell of the electric appliance for house hold and similar purpose, as well as test drop impact resistance of the lamp. Impact Testing Machine
Test sample: Electric appliance, plug and socket, luminaries for house hold and similar purpose
Feature: Comply with the requirement of standard IEC60068-2-75. Cantilever type rack, release the impact element by electromagnet, impact height determined by guide tube. Impact Testing Machine
Parameters:
Model | SH-9 | SH-9A | SH-9B |
Release mode | Electromagnet release | Electromagnet release | Electromagnet release |
Drop floor |
Nylon base 600mm*600mm; thickness 8mm; hardness HRR85-100. |
Nylon base 1000mm*1000mm; thickness 8mm; hardness HRR85-100. |
Hard wood board 114x114x42 mm |
Drop height | 300mm | 0-1000mm adjustable | 457 mm |
Impact hammer | 5J | 2J, 5J, 10J, 20J, 50J(optional) |
Φ50.8mm Cylinder head, weight 4.5kg |
Standards | IEC 60075-2-75 | IEC 60075-2-75 | UL498 |