0.05 Class High-Precision 3-Phase Smart Meter Test Bench

Price negotiation
MOQ 1pcs
Delivery Time 30 days after order confirmed
Brand GENY
Place of Origin CHINA
Certification ISO, CE
Model Number YC1893D
Packaging Details Plywood case
Payment Terms L/C,T/T,D/P
Supply Ability 30 PCS per month

Product Details

Product Specification

Frequency Range 45Hz – 65Hz Place of Origin CHINA
Packaging Details Plywood case Model Number YC1893D
Supply Ability 30 PCS per month Certification ISO, CE
Brand Name GENY Payment Terms L/C,T/T,D/P
Test current output 3x(0.3mA-120A) Test voltage output(Phase-Neutral) 3x(24V-300V)
Price negotiation Delivery Time 30 days after order confirmed
Minimum Order Quantity 1pcs class 0.05

Product Description

0.05 Class High-Precision 3-Phase Smart Meter Test Bench 

Description


• Parallel RS232 Communication Port – simultaneous multi-meter testing of smart meters  
• Rack-Mounted Terminal Calibration – one-click bench verification for test stations  
• Reference Standard Meter Accuracy Testing – traceable precision checks  
• Pre-Warming Cycle – automated stabilization before measurement  
• IEC Accuracy Test Suite – base error, starting current, creeping, repeatability, dial test  
• Influence Quantity Tests – voltage, frequency, reverse phase sequence, voltage unbalance  
• Harmonics & Sub-Harmonics – immunity to odd harmonics and sub-harmonics per IEC standards


Technical Data


Power Supply


Voltage

3 ×230/398V±10%

Frequency

50 / 60Hz ±2Hz

Power capacity

>3 ×3kVA

Ambient temperature

-10°C -- +40°C

Relative humidity

35% -- 85%


Voltage output


Test voltage output(Phase-Neutral)

3x(24V-300V)

Power of the voltage output

3x1000VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h(integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd-21st free programmable


Current Output


Test current output

3x(0.3mA-120A)

Power of the current output

3x1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h(integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd-21st free programmable


Phase Angle


Range

0-360°

Resolution

0.01°

Setting accuracy

0.1°


Frequency


Range

45Hz-65Hz

Resolution

0.01Hz