Price | Negotiable |
MOQ | 1 |
Delivery Time | 5-8 work days |
Brand | Lonroy |
Place of Origin | China |
Packaging Details | Wooden Package |
Payment Terms | L/C, D/A, D/P, T/T, Western Union |
Supply Ability | 200 |
Brand Name | Lonroy | Payment Terms | L/C, D/A, D/P, T/T, Western Union |
Place of Origin | China | Price | Negotiable |
Delivery Time | 5-8 work days | Minimum Order Quantity | 1 |
Packaging Details | Wooden Package | Supply Ability | 200 |
ISO 15989 Automatic Tilt Contact Angle Measuring Instrument Contact Angle Tester
1. Preface
Contact
Angle
refers
to
the
tangent
of
gas-liquid
interface
made
at
the
intersection
of
gas,
liquid
and
solid.
This
tangent
is
in
the
Angle
theta
between
the
liquid
side
and
the
solid-liquid
boundary.
Contact
Angle
measurement
is
the
main
method
of
surface
performance
detection
nowadays.
LR-SDC
-
350
type
the
tilting
contact
Angle
measurement
instrument
is
using
the
principle
of
optical
imaging,
image
contour
analysis
way
to
measure
the
surface
contact
Angle,
wettability,
interfacial
tension
of
table,
surface
energy,
rolling
slip
(Angle),
forward
backward
Angle
and
hysteresis, such
as
performance,
equipment
using
automatic
liquid
into
the
device
and
the
tilting
device
automatically,
fully
functional,
high
cost
performance,
can
meet
the
demand
of
conventional
measurement,
has
been
widely
used
in
many
colleges
and
universities
institutes
and
enterprises.
2.
Instrument
Application
Field
Contact
Angle
measurement
instrument
is
widely
used
in
various
fields,
such
as
mobile
phone
manufacturing,
glass
manufacturing,
surface
treatment,
material
research,
chemical
engineering,
semiconductor
manufacturing,
coating
ink,
electronic
circuit,
textile
fiber,
medical
biology
and
other
fields,
contact
Angle
measurement
has
become
an
important
instrument
to
evaluate
the
surface
performance.
(select
special
accessories
for
some
test
functions)
1.
The
wetting
behavior
of
the
liquid
on
the
solid
surface,
such
as
spreading,
penetration
and
absorption,
is
measured
by
the
static
contact
Angle
with
the
droplet
method;
2.
Measure
the
forward
Angle,
backward
Angle,
contact
Angle
lag,
rolling
Angle
and
dynamic
contact
Angle
of
the
material
on
the
solid
surface;
3.
Continuous
real-time
study
of
absorption
materials,
process
record,
and
analysis
of
contact
Angle
curve
with
time;
4.
Contact
Angle
measurement
of
various
special
materials,
such
as
powder,
curved
surface,
super
hydrophobic/super
hydrophilic
samples;
5.
Test
the
contact
Angle
of
the
material
immersed
in
the
liquid
by
the
adhesive
drop
method;
6.
Measuring
interfacial
tension
of
various
liquid
surfaces
and
their
polarity
and
dispersion
components
by
hanging
drop
method;
7.
Calculate
the
Surface
free
energy
and
its
polar
dispersion
component;
8.
Analysis
of
the
liquid
on
the
solid
surface
adhesion
(Adhersion),
assessment
of
solid
surface
uniformity,
cleanliness,
etc.
3.
Principle
As
shown
in
the
figure
above,
the
contact
Angle
measuring
instrument
is
mainly
composed
of
light
source,
injection
unit,
sample
table,
collection
system,
overall
tilt
platform
and
analysis
software.
The
equipment
adopts
the
principle
of
optical
imaging.
The
light
source
adopts
the
design
of
dense
LED
cold
light
with
uniform
luminescence,
image
cleaning
and
long
service
life.
The
injection
unit
adopts
high
precision
injection
pump,
controlled
by
software
quantitative
and
constant
speed,
stable
drop,
high
precision;
The
sample
table
adopts
3d
manual
fine-tuning
platform,
which
is
flexible
in
operation
and
accurate
in
positioning.
The
sample
table
can
be
customized
according
to
the
actual
sample
size.
The
acquisition
system
adopts
a
black-and-white
imported
CCD
camera,
which
can
take
stable
pictures,
make
the
images
clear
and
reliable.
The
lens
is
equipped
with
German
industrial
import
configuration,
with
adjustable
magnification
of
0.7-4.5
times
and
no
distortion
in
the
imaging.
The
whole
tilting
platform
adopts
software
to
control
tilting
with
high
precision,
with
the
accuracy
as
high
as
0.01°
The
analysis
software
has
a
powerful
function,
with
one-button
automatic
fitting
ability,
with
the
world's
most
advanced
fitting
method,
to
meet
the
precise
fitting
of
various
liquid
droplet
morphology;
4. Specification
Host machine | |
Out size | 750mm(L)*408mm(W)* 695mm(H) |
Weight | 30.5KG |
Power | 220V / 60HZ |
Light source system | |
Light source | Compact LED adjustable blue tone industrial grade cold light source |
Lifelong | Its service life is over 25,000 hours |
Injection unit | |
syringe | Special matching high precision quartz syringe, capacity of 500μL |
dropping liquid | Software control automatic feeding, accuracy up to0.01μL |
Injection unit movement | Up down 50mm; Left right 50mm |
Acquisition system | |
CCD | SONYOriginal imported high-speed industrial chip, 25 frames /S, 130W pixels |
lens | 0.7-4.5 x hd industrial grade continuous variable magnification microscope |
Acquisition system regulation | Front back 100mm (3mm fine tuning), adjustable Angle of view (elevation, top view, 360° rotation and other multi-angle observation) |
Sample table installation | |
Work table size | 120mm*150mm |
Max sample size | 6inch |
Sample table movement |
Front back
movement
manual,
stroke
60mm,
precision
0.1mm Move about manually, stroke 35mm, precision 0.1mm Move up and down manually, stroke 80mm, precision 0.1mm |
Integral sloping platform | Tilt range±90°,tilt accuracy ±0.01°,Tilt rate adjustable |
Analysis software | |
Contact Angle measurement range | 0-180° |
Accuracy of contact Angle measurement | ±0.1° |
Table interface tension measurement range | 0-2000mN/m |
Table interface tension measurement accuracy | 0.01 mN/m |
Analysis software function |
1. The
most
advanced
contact
Angle
measurement
and
analysis
software
in
China
is
automatic
fitting
(one-key
automatic
fitting,There
is
no
human
error)include:Circle
method,(Ellipse/Oblique
ellipse),
LY, (Differential
circle
/
Differential
ellipse); 2. Dynamic contact Angle fitting (batch fitting multiple images) Include(Wettability),(Video analysis);
3.
(Surface
energy);
4.
(Forward
and
backward
angle)
5.
(Rolling
angle)
6.
(Surface
tension);
7.
(Adhesion
work);
|
1.
GB/T
24368-2009(detection
of
hydrophobic
pollutants
on
glass
surface);
2.
SY/
t5153-2007
(reservoir
rock
wettability
measurement
method);
3.
ASTM
D
724-99
(2003)
(test
method
for
surface
wettability
of
paper);
4.
ASTM
d5946-2004
(measurement
of
contact
Angle
between
plastic
film
and
water);
5.
ISO15989
(measurement
of
water
contact
Angle
of
plastic
film
and
thin
plate
corona
treatment
film);
6. Product features
1.
The
host
adopts
high-strength
aviation
aluminum
alloy
structure
and
modular
design
concept,
independently
developed
integrated
chip
circuit
control,
adopts
the
design
essence
and
configuration
of
the
international
top
imported
contact
Angle
equipment,
to
ensure
the
instrument
has
a
strong
stability;
2.
Industrial
grade
dense
adjustable
LED
cold
light
source
system
(life
over
25000H)
is
adopted
to
ensure
a
clearer
image
and
avoid
the
volatilization
of
small
droplets
caused
by
extra
heat;
5.
The
first
domestic
company
to
provide
the
contact
Angle
measurement
and
calibration
sample
imported
from
Germany
to
ensure
the
precision
of
the
instrument,
and
the
Angle
calibration
standard
piece
3°5°8°;
60
°
90
°
120
°;115°
(optional);
6.
Flexible
collection
system
design,
suitable
for
most
of
the
measurement
environment,
simple
to
cope
with
a
variety
of
complex
sample
surface
measurement;
7.
Possess
the
most
advanced
contact
Angle
analysis
method
in
the
world, satisfying
all
kinds
of
liquid.
Accurate
fitting
of
drip
imaging,
including
the
unique
differential
ellipse
of
shengding. And
differential
circle
special
liquid
imaging
fitting
method;
8.
Adopt
the
international
leading
calculation
method,
the
software
has
realized
the
full
automatic
fitting
to
avoid
the
error
caused
by
human
operation;
9. Quick
fitting
function
for
bilateral
contact
Angle
measurement
and
more
comprehensive
quantitative
analysis. Surface
wettability
of
liquids
and
solids
can
be
analyzed
more
accurately. Actual
wettability;
10.
Dynamic
shooting
and
video
fast
test
data,
which
can
continuously
record
the
change
of
test
contact
Angle,
and
then
automatically
batch
fit
by
the
software;
11.
Software
automatically
generates
reports,
which
cover Word
form,
Excel
form,
spectrogram, Various
forms
of
data
reports;
12.
With
a
variety
of
optional
functional
parts,
our
r
&
d
team
is
strong
enough
to
meet
various
customized
measurement
requirements
put
forward
by
customers;
13.
With
the
function
of
forward
and
backward
Angle
measurement,
it
is
convenient
for
the
most
efficient
measurement
of
sample
surface
stability;
14.
Equipped
with
the
rolling
Angle
measurement
function,
which
can
intelligently
distinguish
the
sliding
point
of
material
surface
and
the
forward
and
backward
Angle
measurement
in
this