Price | Negotiable |
MOQ | 1 |
Delivery Time | 5-8 work days |
Brand | Lonroy |
Place of Origin | China |
Model Number | LR-N5200 |
Packaging Details | wooden package |
Supply Ability | 200 pieces |
Brand Name | Lonroy | Place of Origin | China |
Price | Negotiable | Delivery Time | 5-8 work days |
Minimum Order Quantity | 1 | Packaging Details | wooden package |
Dimension | 850mm*410mm*450mm | Model Number | LR-N5200 |
Supply Ability | 200 pieces | Test range | 0.1μm -800μm |
Weight | 30Kg | Test speed | < 1min/ time (excluding sample dispersion time) |
Main
performance
characteristics
★
Advanced
optical
path
design:
LR-N5200
adopts
Fourier
Transform
Detection
(FTD)
technology
to
ensure
maximum
range
with
the
shortest
focal
length,
effectively
improving
the
resolution
of
the
instrument;
the
unique
high-density
detection
unit
makes
THE
LR-N5200
capable
of
detecting
ultra-small
particles.
The
high
density
detection
unit
gives
THE
LR-N5200
a
superb
seamless
full-range
detection
capability.
★
Enable
new
software:
The
third
generation
software
is
officially
commercialized.
The
new
software
optimization
algorithm
makes
the
test
results
more
accurate
and
stable,
and
the
real-time
stored
test
data
will
never
be
lost;
the
third
generation
software
supports
the
fuzzy
search
function,
so
that
all
the
tested
samples
can
be
easily
found
no
matter
how
long
they
have
been
tested
for;
the
human-computer
interaction
is
more
reasonable.
★
Four
generation
detector:
5200
particle
size
meter
at
the
same
time
enabled
the
fourth
generation
detector,
all
imported
German
materials
processing,
oxidation
resistance,
photoelectric
conversion
efficiency
of
more
than
ten
years
almost
zero
attenuation.
LR-N5200
Fully
Sealed
Fiber
Semiconductor
Laser
LR-N5200
adopts
high
stability
and
long
life
Japan
Opnext
Fully
Sealed
Fiber
Semiconductor
Laser,
the
excellent
stability
makes
LR-N5200
has
strong
test
repeatability,
on
the
basis
of
5100-H
to
do
the
laser
power
adjustable,
and
the
maximum
laser
power
has
reached
20MW.
★ Laser
intelligent
management
system:
LP-N5200
is
the
first
to
add
the
laser
intelligent
management
system,
intelligent
management
system
real-time
monitoring
of
the
working
status
of
the
instrument,
once
the
work
command
is
received,
the
intelligent
management
system
will
instantly
light
up
the
laser,
high-performance
laser
will
reach
a
stable
working
state
within
3
seconds.
After
the
sample
test,
the
intelligent
management
system
will
automatically
turn
off
the
laser,
the
laser
will
basically
not
decay.
Theoretically,
the
particle
size
analyzer
can
be
used
without
replacing
the
laser
(optional).
★ Automatic
test:
truly
automatic
test,
what
you
do
is
just
put
in
the
sample,
no
interference
data
without
manual
selection
of
data.
★ Ultrasonic
anti-dry
burning
function:
after
painstaking
research
and
development,
LR-N5200
can
realize
ultrasonic
anti-dry
burning
function,
to
avoid
damage
to
ultrasonic
in
the
case
of
no
water.
★
New
SOP
self-editing
function: In
order
to
meet
the
test
needs
of
different
samples,
LR-N5200
realizes
the
SOP
self-editing
function,
edit
different
test
procedures
according
to
different
samples,
edit
and
save
once
and
then
directly
use
next
time.
Dustproof
and
shockproof
design:
the
whole
instrument
is
sealed
to
greatly
improve
the
service
life
of
the
internal
components. The
unique
shockproof
structure
can
effectively
avoid
the
interference
of
external
vibration
to
the
instrument,
so
that
the
test
results
are
more
stable
and
reliable.
★
Strong
anti-corrosion
design
(optional)
:
It
can
be
equipped
with
acid-resistant,
alkali-resistant,
oil-resistant
(including
all
solvent
oils),
and
organic
solvent-resistant
(such
as
phenol,
n-hexane
and
other
organic
solvents)
according
to
the
actual
needs
of
customers.
★
Optical
path
automatic
calibration:
The
new
self-developed
auto-alignment
system
consists
of
stepper
motors,
precision
guides,
precision
controllers
and
a
software
system
with
a
minimum
step
size
of
1
micron,
which
ensures
that
the
laser
beam
is
focused
through
the
detector
from
the
center
point,
improving
the
accuracy
and
repeatability
of
the
test
results.
The
auto-alignment
system
is
standard
on
all
types
of
laser
particle
sizers.
Unique
microcirculation
system:
The
whole
dispersion
circulation
system
has
been
optimized
design,
more
than
80
ml
of
dispersing
medium
can
be
circulated
test,
truly
realize
the
micro-circulation
test;
optimized
design
to
ensure
that
no
residue
left
after
draining
and
the
accuracy
of
the
next
test
results.
(Optional
micro
test)
★ Free
exhaust
bubble
design: the
new
design
makes
the
whole
test
will
not
have
bubble
into
the
test
sample
window,
avoid
bubble
interference.
Dew
point
measurement
function:
The
system
has
a
dew
point
measurement
function,
and
the
software
can
provide
a
sample
window
fog
reminder
according
to
environmental
changes;
the
instrument
also
has
internal
temperature,
humidity
and
test
medium
temperature
display
function.
organic
solvents
(such
as
phenol,
n-hexane
and
other
organic
solvents).
★
Dispersant
automatic
filling
system: the
new
5200
increased
the
dispersant
automatic
filling
system,
greatly
improving
the
stability
of
the
instrument
dispersion; It
not
only
avoids
the
tedious
artificial
addition
but
also
greatly
prolongs
the
cleaning
cycle
of
the
sample
window
(if
there
is
no
lack
of
dispersant
calcium
carbonate
industry
can
basically
not
clean
the
sample
window).
★ Channel
steel
guide:
the
new
5200
light
path
guide
is
uniformly
upgraded
from
aluminum
alloy
to
thickened
channel
steel,
the
light
path
system
is
more
stable
and
reliable,
and
greatly
reduces
the
influence
of
temperature
and
humidity
on
the
light
path.
★
Sample
no
residue
design: the
instrument
pipeline
and
drainage
structure
are
optimized
design,
the
instrument
pipeline,
circulation
pump
no
liquid
residue,
to
avoid
the
impact
on
the
next
test
data.
★
Sample
window
quick
change
device: newly
designed
sample
window
quick
change
device,
make
sample
window
more
convenient
and
fast
change.
2. Main technical parameters
specifications | LR-N5200(With high) | |
Execution standard | GB/T 19077-2016/ISO 13320:2009 | |
Test range | 0.1μm -800μm | |
Number of detector channels | 70 | |
Accuracy error | < 1% (National standard sample D50 value) | |
Repeatability error | < 0.5% (National standard sample D50 value) | |
Free bubble | With no exhaust bubble design, no bubble interference data more accurate | |
Misoperation protection | The instrument has self-protection function for misoperation and does not respond to misoperation | |
Laser parameter | Imported fiber output high power laser λ= 635nm, P> 10mW | |
The light path calibration | Automatic optical path calibration | |
Dispersion method | ultrasonic | Frequency: F =40KHz, power: P =80W, time: adjustable; With ultrasonic anti-dry burning |
Circulating and stirring | Integrated design of circulation mixing, speed: 100-3950 RPM adjustable speed | |
Circular flow | Rated flow: 0-10L/min Adjustable rated power: 25W | |
The sample pool | Self-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test | |
Microinjection (optional) | The instrument can be equipped with micro automatic test device,10 ml can be cyclic test (optional) | |
Dustproof and shockproof design | The whole machine adopts dustproof and shockproof design | |
Anti-corrosion design (optional) | Can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as phenol, n-hexane and other organic solvents). | |
Software functions | Analysis patterns | Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods |
Statistical methods | Volume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries | |
Statistical comparison | It can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials | |
To DIY | User-defined data to display, according to the percentage of particle size, according to the percentage of particle size or according to | |
According to the template | The percentage of particle size interval is calculated to meet the characterization of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc | |
The test report | The test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion | |
Multilingual support | Chinese and English language interface support, can also be embedded in other languages according to user requirements. | |
Intelligent operation mode | Truly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability. | |
Operating mode | One-click automatic software operation mode | |
The test speed | < 1min/ time (excluding sample dispersion time) | |
volume | 850mm*410mm*450mm | |
The weight of the | 30Kg |