Price | Negotiable |
MOQ | 1 |
Delivery Time | 5-8 work days |
Brand | Lonroy |
Place of Origin | China |
Model Number | LR-N6100 |
Packaging Details | wooden package |
Supply Ability | 200 pieces |
Brand Name | Lonroy | Place of Origin | China |
Price | Negotiable | Delivery Time | 5-8 work days |
Minimum Order Quantity | 1 | Packaging Details | wooden package |
Dimension | 980mm*410mm*450mm | Model Number | LR-N6100 |
Supply Ability | 200 pieces | Test range | 0.1μm -2000μm |
Weight | 35Kg | Test speed | <1min/ time |
ISO 13320 Intelligent Laser Particle Size Analyzer Wet Process 0.1μM-2000μM
1.
Introduction
LR-N6100
adopts
the
most
advanced
Mie
scattering
principle
and
the
conversion
Fourier
transform
optical
path.
High-density
probes
and
full-range
seamless
testing
methods
ensure
the
accuracy
and
repeatability
of
the
test
results.
The
unique
wet
circulation
dispersion
system
ensures
that
there
is
no
particle
deposition
during
the
particle
test
and
no
waste
liquid
accumulation
after
the
test
drainage,
guaranteeing
the
accuracy
of
the
secondary
test
and
making
the
test
results
more
true
and
reliable.
Meanwhile,
a
residue-free
design
is
adopted
to
ensure
the
accuracy
of
detection
for
different
samples.
The
superior
automatic
optical
path
calibration
system
highlights
the
unique
advantages
of
LR-N6100.
LR-N6100
Advanced
optical
path
design:
LR-N6100
adopts
the
spotlight
Fourier
transform
detection
technology
to
ensure
that
the
shortest
focal
length
to
obtain
the
maximum
range,
effectively
improving
the
resolution
of
the
instrument;
unique
high-density
detection
unit,
so
that
the
6100
with
ultra-small
particles
detection
capabilities,
high-density
detection
unit
so
that
the
LR-N6100
with
ultra-all-around
seamless
detection
capabilities,
the
high
version
of
the
dual-optical
path
design.
Dustproof
and
shockproof
design: The
instrument
is
sealed
as
a
whole,
which
greatly
improves
the
service
life
of
the
internal
components.
The
unique
suspension
structure
can
effectively
avoid
the
interference
of
external
vibration
on
the
instrument,
making
the
test
results
more
stable
and
reliable.
★
Optical
path
X,
Y
direction
automatic
calibration:
LR-N6100
uniquely
adopts
the
technology
of
combining
mechanical
center
and
optical
center,
which
makes
the
automatic
adjustment
of
the
optical
path
more
accurate,
reaching
the
micron
level;
at
the
same
time,
the
optical
adjustment
is
faster,
the
fastest
adjustment
can
be
completed
in
15
seconds.
★ Intelligent
automatic
operation
mode:
The
software
realizes
one-button
operation,
automatic
water
intake,
automatic
sampling,
automatic
testing,
automatic
cleaning,
the
whole
testing
process
realizes
one-button
automatic
operation,
easy
to
use.
Unique
micro
circulation
system:
The
entire
dispersion
circulation
system
has
been
optimized
in
design.
When
the
dispersion
medium
reaches
more
than
180ml,
the
circulation
test
can
be
carried
out,
truly
achieving
the
microcirculation
test.
All
joints
adopt
a
quick-plug
and
quick-twist
design,
and
all
pipes
can
be
replaced
in
a
short
time.
The
optimized
design
ensures
that
there
is
no
waste
residue
after
drainage
and
guarantees
the
accuracy
of
the
results
of
the
next
test.
Nkt6100-c
has
a
range
of
0.1
μm
~
2000μm.
Ultrasonic
anti-dry
burning:
LR-N6100
is
equipped
with
100W
high-power
ultrasonic,
and
has
the
function
of
ultrasonic
anti-dry
burning.
★
Misoperation
protection:
LR-N6100 has
self-protection
function,
some
will
damage
the
instrument
misoperation
does
not
respond,
greatly
reduce
the
damage
caused
by
human
misoperation.
★
Dew
point
measurement: sample
window
fog
will
affect
the
accuracy
of
measurement,
such
test
results
have
no
practical
significance,
LR-N6100 with
a
fog
point
measurement
system,
once
the
fog
software
will
automatically
prompt.
★
Free
exhaust
bubble
design: the
new
design
makes
the
whole
test
process
will
not
have
bubbles
into
the
test
sample
window,
to
avoid
the
bubble
interference
(free
exhaust
bubble
function
technology
we
have
the
exclusive).
★
Sample
residue
free
design:
the
instrument
pipeline
and
drainage
structure
are
optimized
design,
the
instrument
pipeline,
circulation
pump
without
liquid
residue,
to
avoid
the
impact
on
the
next
test
data; The
dry
test
was
also
designed
to
be
residue
free.
★
Sample
window
quick
change
device: newly
designed
sample
window
quick
change
device,
make
sample
window
change
more
convenient
and
fast
(20
seconds
to
complete
the
sample
window
disassembly
process).
The
stability
and
repeatability
reach
the
foreign
malvern
instrument
standard
2. Main technical parameters
specifications | LR-N 6100 | |
Execution standard | ISO 13320-1:1999;GB/T19077.1-2008 | |
Test range | 0.1μm -2000μm | |
Number of detector channels | 90 | |
Accuracy error | < 0.5% (National standard sample D50 value) | |
Repeatability error | < 0.5% (National standard sample D50 value) | |
Free bubble | With no exhaust bubble design, no bubble interference data more accurate | |
Misoperation protection | The instrument has self-protection function for misoperation and does not respond to misoperation | |
Laser parameter | Imported fiber output high power laser λ= 635nm, P> 10mW | |
The light path calibration | Automatic optical path calibration | |
Dispersion method | ultrasonic | Frequency: F =40KHz, power: P =80W, time: adjustable; With ultrasonic anti-dry burning |
Circulating and stirring | Integrated design of circulation mixing, speed: 100-33950 RPM adjustable speed | |
Circular flow | Rated flow: 0-30L/min Adjustable rated power: 25W | |
The sample pool | Self-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test | |
Microinjection (optional) | The instrument can be equipped with micro automatic test device,10 ml can be cyclic test (optional) | |
Dustproof and shockproof design | The whole machine adopts dustproof and shockproof design | |
Anti-corrosion design (optional) | Can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as phenol, n-hexane and other organic solvents). | |
Software functions | Analysis patterns | Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods |
Statistical methods | Volume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries | |
Statistical comparison | It can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials | |
DIY display template | The user defines the data to be displayed, and calculates the percentage according to the particle size, the percentage according to the particle size or the percentage according to the particle size interval, so as to meet the characterization method of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc | |
According to the template | The test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion | |
The test report | Chinese and English language interface support, can also be embedded in other languages according to user requirements. | |
Multilingual support | Truly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability. | |
Intelligent operation mode | Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods | |
Operating mode | One-click automatic software operation mode | |
The test speed | < 1min/ time (excluding sample dispersion time) | |
volume | 980mm*410mm*450mm | |
The weight of the | 35Kg |